Logo AND Algorithmique Numérique Distribuée

Public GIT Repository
[mc] Remove the --cfg=model-check:1 flag
[simgrid.git] / doc / doxygen / options.doc
index 528ecd5..89af676 100644 (file)
@@ -64,9 +64,11 @@ int main(int argc, char *argv[]) {
 
 \section options_model Configuring the platform models
 
+\anchor options_storage_model
+\anchor options_vm_model
 \subsection options_model_select Selecting the platform models
 
-SimGrid comes with several network and CPU models built in, and you
+SimGrid comes with several network, CPU and storage models built in, and you
 can change the used model at runtime by changing the passed
 configuration. The three main configuration items are given below.
 For each of these items, passing the special \c help value gives
@@ -74,7 +76,9 @@ you a short description of all possible values. Also, \c --help-models
 should provide information about all models for all existing resources.
    - \b network/model: specify the used network model
    - \b cpu/model: specify the used CPU model
-   - \b workstation/model: specify the used workstation model
+   - \b host/model: specify the used host model
+   - \b storage/model: specify the used storage model (there is currently only one such model - this option is hence only useful for future releases)
+   - \b vm/model: specify the model for virtual machines (there is currently only one such model - this option is hence only useful for future releases)
 
 %As of writing, the following network models are accepted. Over
 the time new models can be added, and some experimental models can be
@@ -114,30 +118,48 @@ If you compiled SimGrid accordingly, you can use packet-level network
 simulators as network models (see \ref pls). In that case, you have
 two extra models, described below, and some \ref options_pls "specific
 additional configuration flags".
-  - \b GTNets: Network pseudo-model using the GTNets simulator instead
-    of an analytic model
   - \b NS3: Network pseudo-model using the NS3 tcp model instead of an
     analytic model
 
 Concerning the CPU, we have only one model for now:
   - \b Cas01: Simplistic CPU model (time=size/power)
 
-The workstation concept is the aggregation of a CPU with a network
+The host concept is the aggregation of a CPU with a network
 card. Three models exists, but actually, only 2 of them are
 interesting. The "compound" one is simply due to the way our internal
 code is organized, and can easily be ignored. So at the end, you have
-two workstation models: The default one allows to aggregate an
+two host models: The default one allows to aggregate an
 existing CPU model with an existing network model, but does not allow
 parallel tasks because these beasts need some collaboration between
 the network and CPU model. That is why, ptask_07 is used by default
 when using SimDag.
-  - \b default: Default workstation model. Currently, CPU:Cas01 and
+  - \b default: Default host model. Currently, CPU:Cas01 and
     network:LV08 (with cross traffic enabled)
-  - \b compound: Workstation model that is automatically chosen if
+  - \b compound: Host model that is automatically chosen if
     you change the network and CPU models
-  - \b ptask_L07: Workstation model somehow similar to Cas01+CM02 but
+  - \b ptask_L07: Host model somehow similar to Cas01+CM02 but
     allowing parallel tasks
 
+\subsection options_generic_plugin Plugins
+
+SimGrid supports the use of plugins; currently, no known plugins
+can be activated but there are use-cases where you may want to write
+your own plugin (for instance, for logging).
+
+Plugins can for instance define own classes that inherit from
+existing classes (for instance, a class "CpuEnergy" inherits from
+"Cpu" to assess energy consumption).
+
+The plugin connects to the code by registering callbacks using
+``surf_callback_register`` (see file ``src/surf/plugins/energy.cpp`` for details).
+
+\verbatim
+    --cfg=plugin:Energy
+\endverbatim
+
+\note
+    This option is case-sensitive: Energy and energy are not the same!
+
 \subsection options_model_optim Optimization level of the platform models
 
 The network and CPU models that are based on lmm_solve (that
@@ -230,7 +252,7 @@ deployment of processes on nodes.
 
 \subsubsection options_model_network_crosstraffic Simulating cross-traffic
 
-%As of SimGrid v3.7, cross-traffic effects can be taken into account in
+As of SimGrid v3.7, cross-traffic effects can be taken into account in
 analytical simulations. It means that ongoing and incoming
 communication flows are treated independently. In addition, the LV08
 model adds 0.05 of usage on the opposite direction for each new
@@ -239,12 +261,12 @@ phenomena such as ack compression.
 
 For that to work, your platform must have two links for each
 pair of interconnected hosts. An example of usable platform is
-available in <tt>examples/msg/gtnets/crosstraffic-p.xml</tt>.
+available in <tt>examples/platforms/crosstraffic.xml</tt>.
 
 This is activated through the \b network/crosstraffic item, that
 can be set to 0 (disable this feature) or 1 (enable it).
 
-Note that with the default workstation model this option is activated by default.
+Note that with the default host model this option is activated by default.
 
 \subsubsection options_model_network_coord Coordinated-based network models
 
@@ -292,19 +314,12 @@ corresponding to the ns3::TcpL4Protocol::SocketType configuration item
 in NS3. The only valid values (enforced on the SimGrid side) are
 'NewReno' or 'Reno' or 'Tahoe'.
 
-When using GTNeTS, two items exist:
- - \b gtnets/jitter, that is a double value to oscillate
-   the link latency, uniformly in random interval
-   [-latency*gtnets_jitter,latency*gtnets_jitter). It defaults to 0.
- - \b gtnets/jitter_seed, the positive seed used to reproduce jitted
-   results. Its value must be in [1,1e8] and defaults to 10.
-
 \section options_modelchecking Configuring the Model-Checking
 
-To enable the experimental SimGrid model-checking support the program should
-be executed with the command line argument
+To enable the SimGrid model-checking support the program should
+be executed using the simgrid-mc wrapper:
 \verbatim
---cfg=model-check:1
+simgrid-mc ./my_program
 \endverbatim
 
 Safety properties are expressed as assertions using the function
@@ -323,10 +338,6 @@ ltl2ba program.
 --cfg=model-check/property:<filename>
 \endverbatim
 
-Of course, specifying a liveness property enables the model-checking
-so that you don't have to give <tt>--cfg=model-check:1</tt> in
-addition.
-
 \subsection options_modelchecking_steps Going for stateful verification
 
 By default, the system is backtracked to its initial state to explore
@@ -344,9 +355,6 @@ setting for your specific system.
 --cfg=model-check/checkpoint:1
 \endverbatim
 
-Of course, specifying this option enables the model-checking so that
-you don't have to give <tt>--cfg=model-check:1</tt> in addition.
-
 \subsection options_modelchecking_reduction Specifying the kind of reduction
 
 The main issue when using the model-checking is the state space
@@ -367,10 +375,6 @@ For now, this configuration variable can take 2 values:
  * dpor: Apply Dynamic Partial Ordering Reduction. Only valid if you
    verify local safety properties.
 
-Of course, specifying a reduction technique enables the model-checking
-so that you don't have to give <tt>--cfg=model-check:1</tt> in
-addition.
-
 \subsection options_modelchecking_visited model-check/visited, Cycle detection
 
 In order to detect cycles, the model-checker needs to check if a new explored
@@ -384,7 +388,7 @@ be removed from the memory and some cycles might be missed.
 
 By default, no state is snapshotted and cycles cannot be detected.
 
-\subsection options_modelchecking_termination, model-check/termination, Non termination detection
+\subsection options_modelchecking_termination model-check/termination, Non termination detection
 
 The \b model-check/termination configuration item can be used to report if a
 non-termination execution path has been found. This is a path with a cycle
@@ -678,6 +682,21 @@ Please, use these two parameters (for comments) to make reproducible
 simulations. For additional details about this and all tracing
 options, check See the \ref tracing_tracing_options.
 
+\section options_msg Configuring MSG
+
+\subsection options_msg_debug_multiple_use Debugging MSG
+
+Sometimes your application may try to send a task that is still being
+executed somewhere else, making it impossible to send this task. However,
+for debugging purposes, one may want to know what the other host is/was
+doing. This option shows a backtrace of the other process.
+
+Enable this option by adding
+
+\verbatim
+--cfg=msg/debug_multiple_use:on
+\endverbatim
+
 \section options_smpi Configuring SMPI
 
 The SMPI interface provides several specific configuration items.
@@ -744,6 +763,12 @@ So, messages with size 65472 and more will get a total of MAX_BANDWIDTH*0.940694
 messages of size 15424 to 65471 will get MAX_BANDWIDTH*0.697866 and so on.
 Here, MAX_BANDWIDTH denotes the bandwidth of the link.
 
+\note
+    The SimGrid-Team has developed a script to help you determine these
+    values. You can find more information and the download here:
+    1. http://simgrid.gforge.inria.fr/contrib/smpi-calibration-doc.html
+    2. http://simgrid.gforge.inria.fr/contrib/smpi-saturation-doc.html
+
 \subsection options_smpi_timing smpi/display_timing: Reporting simulation time
 
 \b Default: 0 (false)
@@ -772,6 +797,12 @@ This is the default value:
 65472:11.6436;15424:3.48845;9376:2.59299;5776:2.18796;3484:1.88101;1426:1.61075;732:1.9503;257:1.95341;0:2.01467
 \endverbatim
 
+\note
+    The SimGrid-Team has developed a script to help you determine these
+    values. You can find more information and the download here:
+    1. http://simgrid.gforge.inria.fr/contrib/smpi-calibration-doc.html
+    2. http://simgrid.gforge.inria.fr/contrib/smpi-saturation-doc.html
+
 \subsection options_smpi_global smpi/privatize_global_variables: Automatic privatization of global variables
 
 MPI executables are meant to be executed in separated processes, but SMPI is
@@ -826,6 +857,63 @@ uses naive version of collective operations). Each collective operation can be m
 The behavior and motivation for this configuration option is identical with \a smpi/test, see
 Section \ref options_model_smpi_test for details.
 
+\subsection options_model_smpi_ois smpi/ois: Inject constant times for asynchronous send operations
+
+This configuration option works exactly as \a smpi/os, see Section \ref options_model_smpi_os.
+Of course, \a smpi/ois is used to account for MPI_Isend instead of MPI_Send.
+
+\subsection options_model_smpi_os smpi/os: Inject constant times for send operations
+
+In several network models such as LogP, send (MPI_Send, MPI_Isend) and receive (MPI_Recv)
+operations incur costs (i.e., they consume CPU time). SMPI can factor these costs in as well, but the
+user has to configure SMPI accordingly as these values may vary by machine.
+This can be done by using smpi/os for MPI_Send operations; for MPI_Isend and
+MPI_Recv, use \a smpi/ois and \a smpi/or, respectively. These work exactly as
+\a smpi/ois.
+
+\a smpi/os can consist of multiple sections; each section takes three values, for example:
+
+\verbatim
+    1:3:2;10:5:1
+\endverbatim
+
+Here, the sections are divided by ";" (that is, this example contains two sections).
+Furthermore, each section consists of three values.
+
+1. The first value denotes the minimum size for this section to take effect;
+   read it as "if message size is greater than this value (and other section has a larger
+   first value that is also smaller than the message size), use this".
+   In the first section above, this value is "1".
+
+2. The second value is the startup time; this is a constant value that will always
+   be charged, no matter what the size of the message. In the first section above,
+   this value is "3".
+
+3. The third value is the \a per-byte cost. That is, it is charged for every
+   byte of the message (incurring cost messageSize*cost_per_byte)
+   and hence accounts also for larger messages. In the first
+   section of the example above, this value is "2".
+
+Now, SMPI always checks which section it should take for a given message; that is,
+if a message of size 11 is sent with the configuration of the example above, only
+the second section will be used, not the first, as the first value of the second
+section is closer to the message size. Hence, a message of size 11 incurs the
+following cost inside MPI_Send:
+
+\verbatim
+    5+11*1
+\endverbatim
+
+%As 5 is the startup cost and 1 is the cost per byte.
+
+\note
+    The order of sections can be arbitrary; they will be ordered internally.
+
+\subsection options_model_smpi_or smpi/or: Inject constant times for receive operations
+
+This configuration option works exactly as \a smpi/os, see Section \ref options_model_smpi_os.
+Of course, \a smpi/or is used to account for MPI_Recv instead of MPI_Send.
+
 \subsection options_model_smpi_test smpi/test: Inject constant times for calls to MPI_Test
 
 \b Default value: 0.0001
@@ -852,6 +940,15 @@ Here is an example:
     to sleep increases linearly with the number of previously failed testk.
 
 
+\subsection options_model_smpi_use_shared_malloc smpi/use_shared_malloc: Use shared memory
+
+\b Default: 1
+
+SMPI can use shared memory by calling shm_* functions; this might speed up the simulation.
+This opens or creates a new POSIX shared memory object, kept in RAM, in /dev/shm.
+
+If you want to disable this behavior, set the value to 0.
+
 \subsection options_model_smpi_wtime smpi/wtime: Inject constant times for calls to MPI_Wtime
 
 \b Default value: 0
@@ -944,7 +1041,7 @@ silently overflow on other parts of the memory.
   for the moment (May 2015).
 
 \note
-  \b Please \b note: You can also pass the command-line option "\b --help" and
+  \b Please \b note: You can also pass the command-line option "--help" and
      "--help-cfg" to an executable that uses simgrid.
 
 - \c clean_atexit: \ref options_generic_clean_atexit
@@ -962,8 +1059,7 @@ silently overflow on other parts of the memory.
 
 - \c exception/cutpath: \ref options_exception_cutpath
 
-- \c gtnets/jitter: \ref options_pls
-- \c gtnets/jitter_seed: \ref options_pls
+- \c host/model: \ref options_model_select
 
 - \c maxmin/precision: \ref options_model_precision
 
@@ -998,6 +1094,8 @@ silently overflow on other parts of the memory.
 - \c network/weight_S: \ref options_model_network_coefs
 
 - \c ns3/TcpModel: \ref options_pls
+- \c path: \ref options_generic_path
+- \c plugin: \ref options_generic_plugin
 
 - \c surf/nthreads: \ref options_model_nthreads
 - \c surf/precision: \ref options_model_precision
@@ -1025,24 +1123,12 @@ silently overflow on other parts of the memory.
 - \c <b>Tracing configuration options can be found in Section \ref tracing_tracing_options</b>.
 
 - \c storage/model: \ref options_storage_model
-- \c path: \ref options_generic_path
-- \c plugin: \ref options_generic_plugin
 - \c verbose-exit: \ref options_generic_exit
 
-- \c vm_workstation/model: \ref options_vm_workstation_model
-- \c workstation/model: \ref options_model_select
+- \c vm/model: \ref options_vm_model
 
 \subsection options_index_smpi_coll Index of SMPI collective algorithms options
-- \c smpi/allgather: \ref options_model_smpi_coll_allgather
-- \c smpi/allgatherv: \ref options_model_smpi_coll_allgatherv
-- \c smpi/allreduce: \ref options_model_smpi_coll_allreduce
-- \c smpi/alltoall: \ref options_model_smpi_coll_alltoall
-- \c smpi/alltoallv: \ref options_model_smpi_coll_alltoallv
-- \c smpi/barrier: \ref options_model_smpi_coll_barrier
-- \c smpi/bcast: \ref options_model_smpi_coll_bcast
-- \c smpi/gather: \ref options_model_smpi_coll_gather
-- \c smpi/reduce: \ref options_model_smpi_coll_reduce
-- \c smpi/reduce_scatter: \ref options_model_smpi_coll_reduce_scatter
-- \c smpi/scatter: \ref options_model_smpi_coll_scatter
+
+TODO: All available collective algorithms will be made available via the ``smpirun --help-coll`` command.
 
 */