From 0afa354891d33f7fb103587b99cca779cf206019 Mon Sep 17 00:00:00 2001 From: Augustin Degomme Date: Mon, 7 Apr 2014 16:05:04 +0200 Subject: [PATCH] also document torus networks --- doc/doxygen/platform.doc | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-) diff --git a/doc/doxygen/platform.doc b/doc/doxygen/platform.doc index 082c96bb20..b9752952fe 100644 --- a/doc/doxygen/platform.doc +++ b/doc/doxygen/platform.doc @@ -364,9 +364,16 @@ unset. \li loopback_bw : bandwidth for loopback (if any). See link section for syntax/details. If both loopback_* attributes are omitted, no loopback link is created and all intra-node communication will - use the main network link of the node. + use the main network link of the node. Loopback link is a FATPIPE. \li loopback_lat : latency for loopback (if any). See link section for syntax/details. See bb_bw for more info. +\li topology : network topology to use. For now SimGrid supports FLAT + (default, with or without backbone, as described before) or + TORUS + attributes for this tag. +\li topo_parameters : specific parameters to pass for the topology + defined in the topology tag. For torus networks, comma-separated list of + the number of nodes in each dimension of the torus. the router name is defined as the resulting String in the following -- 2.20.1