Logo AND Algorithmique Numérique Distribuée

Public GIT Repository
Fix backtrace_dummy
[simgrid.git] / doc / doxygen / options.doc
1 /*! \page options Configure SimGrid
2
3 A number of options can be given at runtime to change the default
4 SimGrid behavior. For a complete list of all configuration options
5 accepted by the SimGrid version used in your simulator, simply pass
6 the --help configuration flag to your program. If some of the options
7 are not documented on this page, this is a bug that you should please
8 report so that we can fix it. Note that some of the options presented
9 here may not be available in your simulators, depending on the
10 @ref install_src_config "compile-time options" that you used.
11
12 \tableofcontents
13
14 \section options_using Passing configuration options to the simulators
15
16 There is several way to pass configuration options to the simulators.
17 The most common way is to use the \c --cfg command line argument. For
18 example, to set the item \c Item to the value \c Value, simply
19 type the following: \verbatim
20 my_simulator --cfg=Item:Value (other arguments)
21 \endverbatim
22
23 Several \c `--cfg` command line arguments can naturally be used. If you
24 need to include spaces in the argument, don't forget to quote the
25 argument. You can even escape the included quotes (write \' for ' if
26 you have your argument between ').
27
28 Another solution is to use the \c \<config\> tag in the platform file. The
29 only restriction is that this tag must occure before the first
30 platform element (be it \c \<AS\>, \c \<cluster\>, \c \<peer\> or whatever).
31 The \c \<config\> tag takes an \c id attribute, but it is currently
32 ignored so you don't really need to pass it. The important par is that
33 within that tag, you can pass one or several \c \<prop\> tags to specify
34 the configuration to use. For example, setting \c Item to \c Value
35 can be done by adding the following to the beginning of your platform
36 file:
37 \verbatim
38 <config>
39   <prop id="Item" value="Value"/>
40 </config>
41 \endverbatim
42
43 A last solution is to pass your configuration directly using the C
44 interface. If you happen to use the MSG interface, this is very easy
45 with the MSG_config() function. If you do not use MSG, that's a bit
46 more complex, as you have to mess with the internal configuration set
47 directly as follows. Check the \ref XBT_config "relevant page" for
48 details on all the functions you can use in this context, \c
49 _sg_cfg_set being the only configuration set currently used in
50 SimGrid.
51
52 @code
53 #include <xbt/config.h>
54
55 extern xbt_cfg_t _sg_cfg_set;
56
57 int main(int argc, char *argv[]) {
58      SD_init(&argc, argv);
59
60      /* Prefer MSG_config() if you use MSG!! */
61      xbt_cfg_set_parse(_sg_cfg_set,"Item:Value");
62
63      // Rest of your code
64 }
65 @endcode
66
67 \section options_model Configuring the platform models
68
69 \anchor options_storage_model
70 \anchor options_vm_model
71 \subsection options_model_select Selecting the platform models
72
73 SimGrid comes with several network, CPU and storage models built in, and you
74 can change the used model at runtime by changing the passed
75 configuration. The three main configuration items are given below.
76 For each of these items, passing the special \c help value gives
77 you a short description of all possible values. Also, \c --help-models
78 should provide information about all models for all existing resources.
79    - \b network/model: specify the used network model
80    - \b cpu/model: specify the used CPU model
81    - \b host/model: specify the used host model
82    - \b storage/model: specify the used storage model (there is currently only one such model - this option is hence only useful for future releases)
83    - \b vm/model: specify the model for virtual machines (there is currently only one such model - this option is hence only useful for future releases)
84
85 %As of writing, the following network models are accepted. Over
86 the time new models can be added, and some experimental models can be
87 removed; check the values on your simulators for an uptodate
88 information. Note that the CM02 model is described in the research report
89 <a href="ftp://ftp.ens-lyon.fr/pub/LIP/Rapports/RR/RR2002/RR2002-40.ps.gz">A
90 Network Model for Simulation of Grid Application</a> while LV08 is
91 described in
92 <a href="http://mescal.imag.fr/membres/arnaud.legrand/articles/simutools09.pdf">Accuracy Study and Improvement of Network Simulation in the SimGrid Framework</a>.
93
94   - \b LV08 (default one): Realistic network analytic model
95     (slow-start modeled by multiplying latency by 10.4, bandwidth by
96     .92; bottleneck sharing uses a payload of S=8775 for evaluating RTT)
97   - \anchor options_model_select_network_constant \b Constant: Simplistic network model where all communication
98     take a constant time (one second). This model provides the lowest
99     realism, but is (marginally) faster.
100   - \b SMPI: Realistic network model specifically tailored for HPC
101     settings (accurate modeling of slow start with correction factors on
102     three intervals: < 1KiB, < 64 KiB, >= 64 KiB). See also \ref
103     options_model_network_coefs "this section" for more info.
104   - \b IB: Realistic network model specifically tailored for HPC
105     settings with InfiniBand networks (accurate modeling contention
106     behavior, based on the model explained in
107     http://mescal.imag.fr/membres/jean-marc.vincent/index.html/PhD/Vienne.pdf).
108     See also \ref options_model_network_coefs "this section" for more info.
109   - \b CM02: Legacy network analytic model (Very similar to LV08, but
110     without corrective factors. The timings of small messages are thus
111     poorly modeled)
112   - \b Reno: Model from Steven H. Low using lagrange_solve instead of
113     lmm_solve (experts only; check the code for more info).
114   - \b Reno2: Model from Steven H. Low using lagrange_solve instead of
115     lmm_solve (experts only; check the code for more info).
116   - \b Vegas: Model from Steven H. Low using lagrange_solve instead of
117     lmm_solve (experts only; check the code for more info).
118
119 If you compiled SimGrid accordingly, you can use packet-level network
120 simulators as network models (see \ref pls_ns3). In that case, you have
121 two extra models, described below, and some \ref options_pls "specific
122 additional configuration flags".
123   - \b NS3: Network pseudo-model using the NS3 tcp model
124
125 Concerning the CPU, we have only one model for now:
126   - \b Cas01: Simplistic CPU model (time=size/power)
127
128 The host concept is the aggregation of a CPU with a network
129 card. Three models exists, but actually, only 2 of them are
130 interesting. The "compound" one is simply due to the way our internal
131 code is organized, and can easily be ignored. So at the end, you have
132 two host models: The default one allows to aggregate an
133 existing CPU model with an existing network model, but does not allow
134 parallel tasks because these beasts need some collaboration between
135 the network and CPU model. That is why, ptask_07 is used by default
136 when using SimDag.
137   - \b default: Default host model. Currently, CPU:Cas01 and
138     network:LV08 (with cross traffic enabled)
139   - \b compound: Host model that is automatically chosen if
140     you change the network and CPU models
141   - \b ptask_L07: Host model somehow similar to Cas01+CM02 but
142     allowing parallel tasks
143
144 \subsection options_generic_plugin Plugins
145
146 SimGrid supports the use of plugins; currently, no known plugins
147 can be activated but there are use-cases where you may want to write
148 your own plugin (for instance, for logging).
149
150 Plugins can for instance define own classes that inherit from
151 existing classes (for instance, a class "CpuEnergy" inherits from
152 "Cpu" to assess energy consumption).
153
154 The plugin connects to the code by registering callbacks using
155 ``signal.connect(callback)`` (see file ``src/surf/plugins/energy.cpp`` for
156 details).
157
158 \verbatim
159     --cfg=plugin:Energy
160 \endverbatim
161
162 \note
163     This option is case-sensitive: Energy and energy are not the same!
164
165 \subsection options_model_optim Optimization level of the platform models
166
167 The network and CPU models that are based on lmm_solve (that
168 is, all our analytical models) accept specific optimization
169 configurations.
170   - items \b network/optim and \b CPU/optim (both default to 'Lazy'):
171     - \b Lazy: Lazy action management (partial invalidation in lmm +
172       heap in action remaining).
173     - \b TI: Trace integration. Highly optimized mode when using
174       availability traces (only available for the Cas01 CPU model for
175       now).
176     - \b Full: Full update of remaining and variables. Slow but may be
177       useful when debugging.
178   - items \b network/maxmin-selective-update and
179     \b cpu/maxmin-selective-update: configure whether the underlying
180     should be lazily updated or not. It should have no impact on the
181     computed timings, but should speed up the computation.
182
183 It is still possible to disable the \c maxmin-selective-update feature
184 because it can reveal counter-productive in very specific scenarios
185 where the interaction level is high. In particular, if all your
186 communication share a given backbone link, you should disable it:
187 without \c maxmin-selective-update, every communications are updated
188 at each step through a simple loop over them. With that feature
189 enabled, every communications will still get updated in this case
190 (because of the dependency induced by the backbone), but through a
191 complicated pattern aiming at following the actual dependencies.
192
193 \subsection options_model_precision Numerical precision of the platform models
194
195 The analytical models handle a lot of floating point values. It is
196 possible to change the epsilon used to update and compare them through
197 the \b maxmin/precision item (default value: 0.00001). Changing it
198 may speedup the simulation by discarding very small actions, at the
199 price of a reduced numerical precision.
200
201 \subsection options_model_nthreads Parallel threads for model updates
202
203 By default, Surf computes the analytical models sequentially to share their
204 resources and update their actions. It is possible to run them in parallel,
205 using the \b surf/nthreads item (default value: 1). If you use a
206 negative or null value, the amount of available cores is automatically
207 detected  and used instead.
208
209 Depending on the workload of the models and their complexity, you may get a
210 speedup or a slowdown because of the synchronization costs of threads.
211
212 \subsection options_model_network Configuring the Network model
213
214 \subsubsection options_model_network_gamma Maximal TCP window size
215
216 The analytical models need to know the maximal TCP window size to take
217 the TCP congestion mechanism into account. This is set to 20000 by
218 default, but can be changed using the \b network/TCP-gamma item.
219
220 On linux, this value can be retrieved using the following
221 commands. Both give a set of values, and you should use the last one,
222 which is the maximal size.\verbatim
223 cat /proc/sys/net/ipv4/tcp_rmem # gives the sender window
224 cat /proc/sys/net/ipv4/tcp_wmem # gives the receiver window
225 \endverbatim
226
227 \subsubsection options_model_network_coefs Correcting important network parameters
228
229 SimGrid can take network irregularities such as a slow startup or
230 changing behavior depending on the message size into account.
231 You should not change these values unless you really know what you're doing.
232
233 The corresponding values were computed through data fitting one the
234 timings of packet-level simulators.
235
236 See
237 <a href="http://mescal.imag.fr/membres/arnaud.legrand/articles/simutools09.pdf">Accuracy Study and Improvement of Network Simulation in the SimGrid Framework</a>
238 for more information about these parameters.
239
240 If you are using the SMPI model, these correction coefficients are
241 themselves corrected by constant values depending on the size of the
242 exchange. Again, only hardcore experts should bother about this fact.
243
244 InfiniBand network behavior can be modeled through 3 parameters, as explained in
245 <a href="http://mescal.imag.fr/membres/jean-marc.vincent/index.html/PhD/Vienne.pdf">this PhD thesis</a>.
246 These factors can be changed through the following option:
247
248 \verbatim
249 smpi/IB-penalty-factors:"βe;βs;γs"
250 \endverbatim
251
252 By default SMPI uses factors computed on the Stampede Supercomputer at TACC, with optimal
253 deployment of processes on nodes.
254
255 \subsubsection options_model_network_crosstraffic Simulating cross-traffic
256
257 %As of SimGrid v3.7, cross-traffic effects can be taken into account in
258 analytical simulations. It means that ongoing and incoming
259 communication flows are treated independently. In addition, the LV08
260 model adds 0.05 of usage on the opposite direction for each new
261 created flow. This can be useful to simulate some important TCP
262 phenomena such as ack compression.
263
264 For that to work, your platform must have two links for each
265 pair of interconnected hosts. An example of usable platform is
266 available in <tt>examples/platforms/crosstraffic.xml</tt>.
267
268 This is activated through the \b network/crosstraffic item, that
269 can be set to 0 (disable this feature) or 1 (enable it).
270
271 Note that with the default host model this option is activated by default.
272
273 \subsubsection options_model_network_coord Coordinated-based network models
274
275 When you want to use network coordinates, as it happens when you use
276 an \<AS\> in your platform file with \c Vivaldi as a routing (see also
277 Section \ref pf_routing_model_vivaldi "Vivaldi Routing Model"), you must
278 set the \b network/coordinates to \c yes so that all mandatory
279 initialization are done in the simulator.
280
281 \subsubsection options_model_network_sendergap Simulating sender gap
282
283 (this configuration item is experimental and may change or disapear)
284
285 It is possible to specify a timing gap between consecutive emission on
286 the same network card through the \b network/sender-gap item. This
287 is still under investigation as of writting, and the default value is
288 to wait 10 microseconds (1e-5 seconds) between emissions.
289
290 \subsubsection options_model_network_asyncsend Simulating asyncronous send
291
292 (this configuration item is experimental and may change or disapear)
293
294 It is possible to specify that messages below a certain size will be sent
295 as soon as the call to MPI_Send is issued, without waiting for the
296 correspondant receive. This threshold can be configured through the
297 \b smpi/async-small-thresh item. The default value is 0. This behavior can also be
298 manually set for MSG mailboxes, by setting the receiving mode of the mailbox
299 with a call to \ref MSG_mailbox_set_async . For MSG, all messages sent to this
300 mailbox will have this behavior, so consider using two mailboxes if needed.
301
302 This value needs to be smaller than or equals to the threshold set at
303 \ref options_model_smpi_detached , because asynchronous messages are
304 meant to be detached as well.
305
306 \subsubsection options_pls Configuring packet-level pseudo-models
307
308 When using the packet-level pseudo-models, several specific
309 configuration flags are provided to configure the associated tools.
310 There is by far not enough such SimGrid flags to cover every aspects
311 of the associated tools, since we only added the items that we
312 needed ourselves. Feel free to request more items (or even better:
313 provide patches adding more items).
314
315 When using NS3, the only existing item is \b ns3/TcpModel,
316 corresponding to the ns3::TcpL4Protocol::SocketType configuration item
317 in NS3. The only valid values (enforced on the SimGrid side) are
318 'NewReno' or 'Reno' or 'Tahoe'.
319
320 \section options_modelchecking Configuring the Model-Checking
321
322 To enable the SimGrid model-checking support the program should
323 be executed using the simgrid-mc wrapper:
324 \verbatim
325 simgrid-mc ./my_program
326 \endverbatim
327
328 Safety properties are expressed as assertions using the function
329 \verbatim
330 void MC_assert(int prop);
331 \endverbatim
332
333 \subsection options_modelchecking_liveness Specifying a liveness property
334
335 If you want to specify liveness properties (beware, that's
336 experimental), you have to pass them on the command line, specifying
337 the name of the file containing the property, as formatted by the
338 ltl2ba program.
339
340 \verbatim
341 --cfg=model-check/property:<filename>
342 \endverbatim
343
344 \subsection options_modelchecking_steps Going for stateful verification
345
346 By default, the system is backtracked to its initial state to explore
347 another path instead of backtracking to the exact step before the fork
348 that we want to explore (this is called stateless verification). This
349 is done this way because saving intermediate states can rapidly
350 exhaust the available memory. If you want, you can change the value of
351 the <tt>model-check/checkpoint</tt> variable. For example, the
352 following configuration will ask to take a checkpoint every step.
353 Beware, this will certainly explode your memory. Larger values are
354 probably better, make sure to experiment a bit to find the right
355 setting for your specific system.
356
357 \verbatim
358 --cfg=model-check/checkpoint:1
359 \endverbatim
360
361 \subsection options_modelchecking_reduction Specifying the kind of reduction
362
363 The main issue when using the model-checking is the state space
364 explosion. To counter that problem, several exploration reduction
365 techniques can be used. There is unfortunately no silver bullet here,
366 and the most efficient reduction techniques cannot be applied to any
367 properties. In particular, the DPOR method cannot be applied on
368 liveness properties since it may break some cycles in the exploration
369 that are important to the property validity.
370
371 \verbatim
372 --cfg=model-check/reduction:<technique>
373 \endverbatim
374
375 For now, this configuration variable can take 2 values:
376  * none: Do not apply any kind of reduction (mandatory for now for
377    liveness properties)
378  * dpor: Apply Dynamic Partial Ordering Reduction. Only valid if you
379    verify local safety properties.
380
381 \subsection options_modelchecking_visited model-check/visited, Cycle detection
382
383 In order to detect cycles, the model-checker needs to check if a new explored
384 state is in fact the same state than a previous one. In order to do this,
385 the model-checker can take a snapshot of each visited state: this snapshot is
386 then used to compare it with subsequent states in the exploration graph.
387
388 The \b model-check/visited is the maximum number of states which are stored in
389 memory. If the maximum number of snapshotted state is reached some states will
390 be removed from the memory and some cycles might be missed.
391
392 By default, no state is snapshotted and cycles cannot be detected.
393
394 \subsection options_modelchecking_termination model-check/termination, Non termination detection
395
396 The \b model-check/termination configuration item can be used to report if a
397 non-termination execution path has been found. This is a path with a cycle
398 which means that the program might never terminate.
399
400 This only works in safety mode.
401
402 This options is disabled by default.
403
404 \subsection options_modelchecking_dot_output model-check/dot-output, Dot output
405
406 If set, the \b model-check/dot-output configuration item is the name of a file
407 in which to write a dot file of the path leading the found property (safety or
408 liveness violation) as well as the cycle for liveness properties. This dot file
409 can then fed to the graphviz dot tool to generate an corresponding graphical
410 representation.
411
412 \subsection options_modelchecking_max_depth model-check/max_depth, Depth limit
413
414 The \b model-checker/max-depth can set the maximum depth of the exploration
415 graph of the model-checker. If this limit is reached, a logging message is
416 sent and the results might not be exact.
417
418 By default, there is not depth limit.
419
420 \subsection options_modelchecking_timeout Handling of timeout
421
422 By default, the model-checker does not handle timeout conditions: the `wait`
423 operations never time out. With the \b model-check/timeout configuration item
424 set to \b yes, the model-checker will explore timeouts of `wait` operations.
425
426 \subsection options_modelchecking_comm_determinism Communication determinism
427
428 The \b model-check/communications-determinism and
429 \b model-check/send-determinism items can be used to select the communication
430 determinism mode of the model-checker which checks determinism properties of
431 the communications of an application.
432
433 \subsection options_modelchecking_sparse_checkpoint Per page checkpoints
434
435 When the model-checker is configured to take a snapshot of each explored state
436 (with the \b model-checker/visited item), the memory consumption can rapidly
437 reach GiB ou Tib of memory. However, for many workloads, the memory does not
438 change much between different snapshots and taking a complete copy of each
439 snapshot is a waste of memory.
440
441 The \b model-check/sparse-checkpoint option item can be set to \b yes in order
442 to avoid making a complete copy of each snapshot: instead, each snapshot will be
443 decomposed in blocks which will be stored separately.
444 If multiple snapshots share the same block (or if the same block
445 is used in the same snapshot), the same copy of the block will be shared leading
446 to a reduction of the memory footprint.
447
448 For many applications, this option considerably reduces the memory consumption.
449 In somes cases, the model-checker might be slightly slower because of the time
450 taken to manage the metadata about the blocks. In other cases however, this
451 snapshotting strategy will be much faster by reducing the cache consumption.
452 When the memory consumption is important, by avoiding to hit the swap or
453 reducing the swap usage, this option might be much faster than the basic
454 snapshotting strategy.
455
456 This option is currently disabled by default.
457
458 \subsection options_mc_perf Performance considerations for the model checker
459
460 The size of the stacks can have a huge impact on the memory
461 consumption when using model-checking. By default, each snapshot will
462 save a copy of the whole stacks and not only of the part which is
463 really meaningful: you should expect the contribution of the memory
464 consumption of the snapshots to be \f$ \mbox{number of processes}
465 \times \mbox{stack size} \times \mbox{number of states} \f$.
466
467 The \b model-check/sparse-checkpoint can be used to reduce the memory
468 consumption by trying to share memory between the different snapshots.
469
470 When compiled against the model checker, the stacks are not
471 protected with guards: if the stack size is too small for your
472 application, the stack will silently overflow on other parts of the
473 memory.
474
475 \subsection options_modelchecking_hash Hashing of the state (experimental)
476
477 Usually most of the time of the model-checker is spent comparing states. This
478 process is complicated and consumes a lot of bandwidth and cache.
479 In order to speedup the state comparison, the experimental \b model-checker/hash
480 configuration item enables the computation of a hash summarizing as much
481 information of the state as possible into a single value. This hash can be used
482 to avoid most of the comparisons: the costly comparison is then only used when
483 the hashes are identical.
484
485 Currently most of the state is not included in the hash because the
486 implementation was found to be buggy and this options is not as useful as
487 it could be. For this reason, it is currently disabled by default.
488
489 \subsection options_modelchecking_recordreplay Record/replay (experimental)
490
491 As the model-checker keeps jumping at different places in the execution graph,
492 it is difficult to understand what happens when trying to debug an application
493 under the model-checker. Event the output of the program is difficult to
494 interpret. Moreover, the model-checker does not behave nicely with advanced
495 debugging tools such as valgrind. For those reason, to identify a trajectory
496 in the execution graph with the model-checker and replay this trajcetory and
497 without the model-checker black-magic but with more standard tools
498 (such as a debugger, valgrind, etc.). For this reason, Simgrid implements an
499 experimental record/replay functionnality in order to record a trajectory with
500 the model-checker and replay it without the model-checker.
501
502 When the model-checker finds an interesting path in the application execution
503 graph (where a safety or liveness property is violated), it can generate an
504 identifier for this path. In order to enable this behavious the
505 \b model-check/record must be set to \b yes. By default, this behaviour is not
506 enabled.
507
508 This is an example of output:
509
510 <pre>
511 [  0.000000] (0:@) Check a safety property
512 [  0.000000] (0:@) **************************
513 [  0.000000] (0:@) *** PROPERTY NOT VALID ***
514 [  0.000000] (0:@) **************************
515 [  0.000000] (0:@) Counter-example execution trace:
516 [  0.000000] (0:@) Path = 1/3;1/4
517 [  0.000000] (0:@) [(1)Tremblay (app)] MC_RANDOM(3)
518 [  0.000000] (0:@) [(1)Tremblay (app)] MC_RANDOM(4)
519 [  0.000000] (0:@) Expanded states = 27
520 [  0.000000] (0:@) Visited states = 68
521 [  0.000000] (0:@) Executed transitions = 46
522 </pre>
523
524 This path can then be replayed outside of the model-checker (and even in
525 non-MC build of simgrid) by setting the \b model-check/replay item to the given
526 path. The other options should be the same (but the model-checker should
527 be disabled).
528
529 The format and meaning of the path may change between different releases so
530 the same release of Simgrid should be used for the record phase and the replay
531 phase.
532
533 \section options_virt Configuring the User Process Virtualization
534
535 \subsection options_virt_factory Selecting the virtualization factory
536
537 In SimGrid, the user code is virtualized in a specific mechanism
538 that allows the simulation kernel to control its execution: when a user
539 process requires a blocking action (such as sending a message), it is
540 interrupted, and only gets released when the simulated clock reaches
541 the point where the blocking operation is done.
542
543 In SimGrid, the containers in which user processes are virtualized are
544 called contexts. Several context factory are provided, and you can
545 select the one you want to use with the \b contexts/factory
546 configuration item. Some of the following may not exist on your
547 machine because of portability issues. In any case, the default one
548 should be the most effcient one (please report bugs if the
549 auto-detection fails for you). They are sorted here from the slowest
550 to the most effient:
551  - \b thread: very slow factory using full featured threads (either
552    pthreads or windows native threads)
553  - \b ucontext: fast factory using System V contexts (or a portability
554    layer of our own on top of Windows fibers)
555  - \b raw: amazingly fast factory using a context switching mechanism
556    of our own, directly implemented in assembly (only available for x86
557    and amd64 platforms for now)
558  - \b boost: This uses the [context implementation](http://www.boost.org/doc/libs/1_59_0/libs/context/doc/html/index.html)
559              of the boost library; you must have this library installed before
560              you compile SimGrid. (On Debian GNU/Linux based systems, this is
561              provided by the libboost-contexts-dev package.)
562
563 The only reason to change this setting is when the debugging tools get
564 fooled by the optimized context factories. Threads are the most
565 debugging-friendly contextes, as they allow to set breakpoints anywhere with gdb
566  and visualize backtraces for all processes, in order to debug concurrency issues.
567 Valgrind is also more comfortable with threads, but it should be usable with all factories.
568
569 \subsection options_virt_stacksize Adapting the used stack size
570
571 Each virtualized used process is executed using a specific system
572 stack. The size of this stack has a huge impact on the simulation
573 scalability, but its default value is rather large. This is because
574 the error messages that you get when the stack size is too small are
575 rather disturbing: this leads to stack overflow (overwriting other
576 stacks), leading to segfaults with corrupted stack traces.
577
578 If you want to push the scalability limits of your code, you might
579 want to reduce the \b contexts/stack-size item. Its default value
580 is 8192 (in KiB), while our Chord simulation works with stacks as small
581 as 16 KiB, for example. For the thread factory, the default value
582 is the one of the system, if it is too large/small, it has to be set
583 with this parameter.
584
585 The operating system should only allocate memory for the pages of the
586 stack which are actually used and you might not need to use this in
587 most cases. However, this setting is very important when using the
588 model checker (see \ref options_mc_perf).
589
590 In some cases, no stack guard page is used and the stack will silently
591 overflow on other parts of the memory if the stack size is too small
592 for your application. This happens :
593
594 - on Windows systems;
595 - when the model checker is enabled;
596 - when stack guard pages are explicitely disabled (see \ref  options_perf_guard_size).
597
598 \subsection options_virt_parallel Running user code in parallel
599
600 Parallel execution of the user code is only considered stable in
601 SimGrid v3.7 and higher. It is described in
602 <a href="http://hal.inria.fr/inria-00602216/">INRIA RR-7653</a>.
603
604 If you are using the \c ucontext or \c raw context factories, you can
605 request to execute the user code in parallel. Several threads are
606 launched, each of them handling as much user contexts at each run. To
607 actiave this, set the \b contexts/nthreads item to the amount of
608 cores that you have in your computer (or lower than 1 to have
609 the amount of cores auto-detected).
610
611 Even if you asked several worker threads using the previous option,
612 you can request to start the parallel execution (and pay the
613 associated synchronization costs) only if the potential parallelism is
614 large enough. For that, set the \b contexts/parallel-threshold
615 item to the minimal amount of user contexts needed to start the
616 parallel execution. In any given simulation round, if that amount is
617 not reached, the contexts will be run sequentially directly by the
618 main thread (thus saving the synchronization costs). Note that this
619 option is mainly useful when the grain of the user code is very fine,
620 because our synchronization is now very efficient.
621
622 When parallel execution is activated, you can choose the
623 synchronization schema used with the \b contexts/synchro item,
624 which value is either:
625  - \b futex: ultra optimized synchronisation schema, based on futexes
626    (fast user-mode mutexes), and thus only available on Linux systems.
627    This is the default mode when available.
628  - \b posix: slow but portable synchronisation using only POSIX
629    primitives.
630  - \b busy_wait: not really a synchronisation: the worker threads
631    constantly request new contexts to execute. It should be the most
632    efficient synchronisation schema, but it loads all the cores of your
633    machine for no good reason. You probably prefer the other less
634    eager schemas.
635
636 \section options_tracing Configuring the tracing subsystem
637
638 The \ref outcomes_vizu "tracing subsystem" can be configured in several
639 different ways depending on the nature of the simulator (MSG, SimDag,
640 SMPI) and the kind of traces that need to be obtained. See the \ref
641 tracing_tracing_options "Tracing Configuration Options subsection" to
642 get a detailed description of each configuration option.
643
644 We detail here a simple way to get the traces working for you, even if
645 you never used the tracing API.
646
647
648 - Any SimGrid-based simulator (MSG, SimDag, SMPI, ...) and raw traces:
649 \verbatim
650 --cfg=tracing:yes --cfg=tracing/uncategorized:yes --cfg=triva/uncategorized:uncat.plist
651 \endverbatim
652     The first parameter activates the tracing subsystem, the second
653     tells it to trace host and link utilization (without any
654     categorization) and the third creates a graph configuration file
655     to configure Triva when analysing the resulting trace file.
656
657 - MSG or SimDag-based simulator and categorized traces (you need to declare categories and classify your tasks according to them)
658 \verbatim
659 --cfg=tracing:yes --cfg=tracing/categorized:yes --cfg=triva/categorized:cat.plist
660 \endverbatim
661     The first parameter activates the tracing subsystem, the second
662     tells it to trace host and link categorized utilization and the
663     third creates a graph configuration file to configure Triva when
664     analysing the resulting trace file.
665
666 - SMPI simulator and traces for a space/time view:
667 \verbatim
668 smpirun -trace ...
669 \endverbatim
670     The <i>-trace</i> parameter for the smpirun script runs the
671 simulation with --cfg=tracing:yes and --cfg=tracing/smpi:yes. Check the
672 smpirun's <i>-help</i> parameter for additional tracing options.
673
674 Sometimes you might want to put additional information on the trace to
675 correctly identify them later, or to provide data that can be used to
676 reproduce an experiment. You have two ways to do that:
677
678 - Add a string on top of the trace file as comment:
679 \verbatim
680 --cfg=tracing/comment:my_simulation_identifier
681 \endverbatim
682
683 - Add the contents of a textual file on top of the trace file as comment:
684 \verbatim
685 --cfg=tracing/comment-file:my_file_with_additional_information.txt
686 \endverbatim
687
688 Please, use these two parameters (for comments) to make reproducible
689 simulations. For additional details about this and all tracing
690 options, check See the \ref tracing_tracing_options.
691
692 \section options_msg Configuring MSG
693
694 \subsection options_msg_debug_multiple_use Debugging MSG
695
696 Sometimes your application may try to send a task that is still being
697 executed somewhere else, making it impossible to send this task. However,
698 for debugging purposes, one may want to know what the other host is/was
699 doing. This option shows a backtrace of the other process.
700
701 Enable this option by adding
702
703 \verbatim
704 --cfg=msg/debug-multiple-use:on
705 \endverbatim
706
707 \section options_smpi Configuring SMPI
708
709 The SMPI interface provides several specific configuration items.
710 These are uneasy to see since the code is usually launched through the
711 \c smiprun script directly.
712
713 \subsection options_smpi_bench smpi/bench: Automatic benchmarking of SMPI code
714
715 In SMPI, the sequential code is automatically benchmarked, and these
716 computations are automatically reported to the simulator. That is to
717 say that if you have a large computation between a \c MPI_Recv() and a
718 \c MPI_Send(), SMPI will automatically benchmark the duration of this
719 code, and create an execution task within the simulator to take this
720 into account. For that, the actual duration is measured on the host
721 machine and then scaled to the power of the corresponding simulated
722 machine. The variable \b smpi/running-power allows to specify the
723 computational power of the host machine (in flop/s) to use when
724 scaling the execution times. It defaults to 20000, but you really want
725 to update it to get accurate simulation results.
726
727 When the code is constituted of numerous consecutive MPI calls, the
728 previous mechanism feeds the simulation kernel with numerous tiny
729 computations. The \b smpi/cpu-threshold item becomes handy when this
730 impacts badly the simulation performance. It specifies a threshold (in
731 seconds) below which the execution chunks are not reported to the
732 simulation kernel (default value: 1e-6).
733
734
735 \note
736     The option smpi/cpu-threshold ignores any computation time spent
737     below this threshold. SMPI does not consider the \a amount of these
738     computations; there is no offset for this. Hence, by using a
739     value that is too low, you may end up with unreliable simulation
740     results.
741
742  In some cases, however, one may wish to disable simulation of
743 application computation. This is the case when SMPI is used not to
744 simulate an MPI applications, but instead an MPI code that performs
745 "live replay" of another MPI app (e.g., ScalaTrace's replay tool,
746 various on-line simulators that run an app at scale). In this case the
747 computation of the replay/simulation logic should not be simulated by
748 SMPI. Instead, the replay tool or on-line simulator will issue
749 "computation events", which correspond to the actual MPI simulation
750 being replayed/simulated. At the moment, these computation events can
751 be simulated using SMPI by calling internal smpi_execute*() functions.
752
753 To disable the benchmarking/simulation of computation in the simulated
754 application, the variable \b smpi/simulate-computation should be set to no.
755 Equivalently, setting \b smpi/cpu-threshold to -1 also ignores all
756 computation.
757
758 \note
759     This option just ignores the timings in your simulation; it still executes
760     the computations itself. If you want to stop SMPI from doing that,
761     you should check the SMPI_SAMPLE macros, documented in the chapter
762     \ref SMPI_adapting_speed.
763
764 \subsection options_model_smpi_adj_file smpi/comp-adjustment-file: Slow-down or speed-up parts of your code.
765
766 This option allows you to pass a file that contains two columns: The first column
767 defines the section that will be subject to a speedup; the second column is the speedup.
768
769 For instance:
770
771 \verbatim
772 "start:stop","ratio"
773 "exchange_1.f:30:exchange_1.f:130",1.18244559422142
774 \endverbatim
775
776 The first line is the header - you must include it.
777 The following line means that the code between two consecutive MPI calls on
778 line 30 in exchange_1.f and line 130 in exchange_1.f should receive a speedup
779 of 1.18244559422142. The value for the second column is therefore a speedup, if it is
780 larger than 1 and a slow-down if it is smaller than 1. Nothing will be changed if it is
781 equal to 1.
782
783 Of course, you can set any arbitrary filenames you want (so the start and end don't have to be
784 in the same file), but be aware that this mechanism only supports @em consecutive calls!
785
786 \note
787     Please note that you must pass the \b -trace-call-location flag to smpicc
788     or smpiff, respectively! This flag activates some macro definitions in our
789     mpi.h / mpi.f files that help with obtaining the call location.
790
791 \subsection options_model_smpi_bw_factor smpi/bw-factor: Bandwidth factors
792
793 The possible throughput of network links is often dependent on the
794 message sizes, as protocols may adapt to different message sizes. With
795 this option, a series of message sizes and factors are given, helping
796 the simulation to be more realistic. For instance, the current
797 default value is
798
799 \verbatim
800 65472:0.940694;15424:0.697866;9376:0.58729;5776:1.08739;3484:0.77493;1426:0.608902;732:0.341987;257:0.338112;0:0.812084
801 \endverbatim
802
803 So, messages with size 65472 and more will get a total of MAX_BANDWIDTH*0.940694,
804 messages of size 15424 to 65471 will get MAX_BANDWIDTH*0.697866 and so on.
805 Here, MAX_BANDWIDTH denotes the bandwidth of the link.
806
807 \note
808     The SimGrid-Team has developed a script to help you determine these
809     values. You can find more information and the download here:
810     1. http://simgrid.gforge.inria.fr/contrib/smpi-calibration-doc.html
811     2. http://simgrid.gforge.inria.fr/contrib/smpi-saturation-doc.html
812
813 \subsection options_smpi_timing smpi/display-timing: Reporting simulation time
814
815 \b Default: 0 (false)
816
817 Most of the time, you run MPI code with SMPI to compute the time it
818 would take to run it on a platform. But since the
819 code is run through the \c smpirun script, you don't have any control
820 on the launcher code, making it difficult to report the simulated time
821 when the simulation ends. If you set the \b smpi/display-timing item
822 to 1, \c smpirun will display this information when the simulation ends. \verbatim
823 Simulation time: 1e3 seconds.
824 \endverbatim
825
826 \subsection options_model_smpi_lat_factor smpi/lat-factor: Latency factors
827
828 The motivation and syntax for this option is identical to the motivation/syntax
829 of smpi/bw-factor, see \ref options_model_smpi_bw_factor for details.
830
831 There is an important difference, though: While smpi/bw-factor \a reduces the
832 actual bandwidth (i.e., values between 0 and 1 are valid), latency factors
833 increase the latency, i.e., values larger than or equal to 1 are valid here.
834
835 This is the default value:
836
837 \verbatim
838 65472:11.6436;15424:3.48845;9376:2.59299;5776:2.18796;3484:1.88101;1426:1.61075;732:1.9503;257:1.95341;0:2.01467
839 \endverbatim
840
841 \note
842     The SimGrid-Team has developed a script to help you determine these
843     values. You can find more information and the download here:
844     1. http://simgrid.gforge.inria.fr/contrib/smpi-calibration-doc.html
845     2. http://simgrid.gforge.inria.fr/contrib/smpi-saturation-doc.html
846
847 \subsection options_smpi_global smpi/privatize-global-variables: Automatic privatization of global variables
848
849 MPI executables are meant to be executed in separated processes, but SMPI is
850 executed in only one process. Global variables from executables will be placed
851 in the same memory zone and shared between processes, causing hard to find bugs.
852 To avoid this, several options are possible :
853   - Manual edition of the code, for example to add __thread keyword before data
854   declaration, which allows the resulting code to work with SMPI, but only
855   if the thread factory (see \ref options_virt_factory) is used, as global
856   variables are then placed in the TLS (thread local storage) segment.
857   - Source-to-source transformation, to add a level of indirection
858   to the global variables. SMPI does this for F77 codes compiled with smpiff,
859   and used to provide coccinelle scripts for C codes, which are not functional anymore.
860   - Compilation pass, to have the compiler automatically put the data in
861   an adapted zone.
862   - Runtime automatic switching of the data segments. SMPI stores a copy of
863   each global data segment for each process, and at each context switch replaces
864   the actual data with its copy from the right process. This mechanism uses mmap,
865   and is for now limited to systems supporting this functionnality (all Linux
866   and some BSD should be compatible).
867   Another limitation is that SMPI only accounts for global variables defined in
868   the executable. If the processes use external global variables from dynamic
869   libraries, they won't be switched correctly. To avoid this, using static
870   linking is advised (but not with the simgrid library, to avoid replicating
871   its own global variables).
872
873   To use this runtime automatic switching, the variable \b smpi/privatize-global-variables
874   should be set to yes
875
876 \warning
877   This configuration option cannot be set in your platform file. You can only
878   pass it as an argument to smpirun.
879
880
881 \subsection options_model_smpi_detached Simulating MPI detached send
882
883 This threshold specifies the size in bytes under which the send will return
884 immediately. This is different from the threshold detailed in  \ref options_model_network_asyncsend
885 because the message is not effectively sent when the send is posted. SMPI still waits for the
886 correspondant receive to be posted to perform the communication operation. This threshold can be set
887 by changing the \b smpi/send-is-detached-thresh item. The default value is 65536.
888
889 \subsection options_model_smpi_collectives Simulating MPI collective algorithms
890
891 SMPI implements more than 100 different algorithms for MPI collective communication, to accurately
892 simulate the behavior of most of the existing MPI libraries. The \b smpi/coll-selector item can be used
893  to use the decision logic of either OpenMPI or MPICH libraries (values: ompi or mpich, by default SMPI
894 uses naive version of collective operations). Each collective operation can be manually selected with a
895 \b smpi/collective_name:algo_name. Available algorithms are listed in \ref SMPI_collective_algorithms .
896
897 \subsection options_model_smpi_iprobe smpi/iprobe: Inject constant times for calls to MPI_Iprobe
898
899 \b Default value: 0.0001
900
901 The behavior and motivation for this configuration option is identical with \a smpi/test, see
902 Section \ref options_model_smpi_test for details.
903
904 \subsection options_model_smpi_init smpi/init: Inject constant times for calls to MPI_Init
905
906 \b Default value: 0
907
908 The behavior for this configuration option is identical with \a smpi/test, see
909 Section \ref options_model_smpi_test for details.
910
911 \subsection options_model_smpi_ois smpi/ois: Inject constant times for asynchronous send operations
912
913 This configuration option works exactly as \a smpi/os, see Section \ref options_model_smpi_os.
914 Of course, \a smpi/ois is used to account for MPI_Isend instead of MPI_Send.
915
916 \subsection options_model_smpi_os smpi/os: Inject constant times for send operations
917
918 In several network models such as LogP, send (MPI_Send, MPI_Isend) and receive (MPI_Recv)
919 operations incur costs (i.e., they consume CPU time). SMPI can factor these costs in as well, but the
920 user has to configure SMPI accordingly as these values may vary by machine.
921 This can be done by using smpi/os for MPI_Send operations; for MPI_Isend and
922 MPI_Recv, use \a smpi/ois and \a smpi/or, respectively. These work exactly as
923 \a smpi/ois.
924
925 \a smpi/os can consist of multiple sections; each section takes three values, for example:
926
927 \verbatim
928     1:3:2;10:5:1
929 \endverbatim
930
931 Here, the sections are divided by ";" (that is, this example contains two sections).
932 Furthermore, each section consists of three values.
933
934 1. The first value denotes the minimum size for this section to take effect;
935    read it as "if message size is greater than this value (and other section has a larger
936    first value that is also smaller than the message size), use this".
937    In the first section above, this value is "1".
938
939 2. The second value is the startup time; this is a constant value that will always
940    be charged, no matter what the size of the message. In the first section above,
941    this value is "3".
942
943 3. The third value is the \a per-byte cost. That is, it is charged for every
944    byte of the message (incurring cost messageSize*cost_per_byte)
945    and hence accounts also for larger messages. In the first
946    section of the example above, this value is "2".
947
948 Now, SMPI always checks which section it should take for a given message; that is,
949 if a message of size 11 is sent with the configuration of the example above, only
950 the second section will be used, not the first, as the first value of the second
951 section is closer to the message size. Hence, a message of size 11 incurs the
952 following cost inside MPI_Send:
953
954 \verbatim
955     5+11*1
956 \endverbatim
957
958 %As 5 is the startup cost and 1 is the cost per byte.
959
960 \note
961     The order of sections can be arbitrary; they will be ordered internally.
962
963 \subsection options_model_smpi_or smpi/or: Inject constant times for receive operations
964
965 This configuration option works exactly as \a smpi/os, see Section \ref options_model_smpi_os.
966 Of course, \a smpi/or is used to account for MPI_Recv instead of MPI_Send.
967
968 \subsection options_model_smpi_test smpi/test: Inject constant times for calls to MPI_Test
969
970 \b Default value: 0.0001
971
972 By setting this option, you can control the amount of time a process sleeps
973 when MPI_Test() is called; this is important, because SimGrid normally only
974 advances the time while communication is happening and thus,
975 MPI_Test will not add to the time, resulting in a deadlock if used as a
976 break-condition.
977
978 Here is an example:
979
980 \code{.unparsed}
981     while(!flag) {
982         MPI_Test(request, flag, status);
983         ...
984     }
985 \endcode
986
987 \note
988     Internally, in order to speed up execution, we use a counter to keep track
989     on how often we already checked if the handle is now valid or not. Hence, we
990     actually use counter*SLEEP_TIME, that is, the time MPI_Test() causes the process
991     to sleep increases linearly with the number of previously failed testk.
992
993
994 \subsection options_model_smpi_use_shared_malloc smpi/use-shared-malloc: Factorize malloc()s
995
996 \b Default: 1
997
998 SMPI can use shared memory by calling shm_* functions; this might speed up the simulation.
999 This opens or creates a new POSIX shared memory object, kept in RAM, in /dev/shm.
1000
1001 If you want to disable this behavior, set the value to 0.
1002
1003 \subsection options_model_smpi_wtime smpi/wtime: Inject constant times for calls to MPI_Wtime
1004
1005 \b Default value: 0
1006
1007 By setting this option, you can control the amount of time a process sleeps
1008 when MPI_Wtime() is called; this is important, because SimGrid normally only
1009 advances the time while communication is happening and thus,
1010 MPI_Wtime will not add to the time, resulting in a deadlock if used as a
1011 break-condition.
1012
1013 Here is an example:
1014
1015 \code{.unparsed}
1016     while(MPI_Wtime() < some_time_bound) {
1017         ...
1018     }
1019 \endcode
1020
1021 If the time is never advanced, this loop will clearly never end as MPI_Wtime()
1022 always returns the same value. Hence, pass a (small) value to the smpi/wtime
1023 option to force a call to MPI_Wtime to advance the time as well.
1024
1025
1026 \section options_generic Configuring other aspects of SimGrid
1027
1028 \subsection options_generic_clean_atexit Cleanup before termination
1029
1030 The C / C++ standard contains a function called \b [atexit](http://www.cplusplus.com/reference/cstdlib/atexit/).
1031 atexit registers callbacks, which are called just before the program terminates.
1032
1033 By setting the configuration option clean-atexit to 1 (true), a callback
1034 is registered and will clean up some variables and terminate/cleanup the tracing.
1035
1036 TODO: Add when this should be used.
1037
1038 \subsection options_generic_path XML file inclusion path
1039
1040 It is possible to specify a list of directories to search into for the
1041 \<include\> tag in XML files by using the \b path configuration
1042 item. To add several directory to the path, set the configuration
1043 item several times, as in \verbatim
1044 --cfg=path:toto --cfg=path:tutu
1045 \endverbatim
1046
1047 \subsection options_generic_exit Behavior on Ctrl-C
1048
1049 By default, when Ctrl-C is pressed, the status of all existing
1050 simulated processes is displayed before exiting the simulation. This is very useful to debug your
1051 code, but it can reveal troublesome in some cases (such as when the
1052 amount of processes becomes really big). This behavior is disabled
1053 when \b verbose-exit is set to 0 (it is to 1 by default).
1054
1055 \subsection options_exception_cutpath Truncate local path from exception backtrace
1056
1057 \verbatim
1058 --cfg=exceptions/cutpath:1
1059 \endverbatim
1060
1061 <b>This configuration option is an internal option and should normally not be used
1062 by the user.</b> It is used to remove the path from the backtrace
1063 shown when an exception is thrown; if we didn't remove this part, the tests
1064 testing the exception parts of simgrid would fail on most machines, as we are
1065 currently comparing output. Clearly, the path used on different machines are almost
1066 guaranteed to be different and hence, the output would
1067 mismatch, causing the test to fail.
1068
1069 \section options_log Logging Configuration
1070
1071 It can be done by using XBT. Go to \ref XBT_log for more details.
1072
1073 \section options_perf Performance optimizations
1074
1075 \subsection options_perf_context Context factory
1076
1077 In order to achieve higher performance, you might want to use the raw
1078 context factory which avoids any system call when switching between
1079 tasks. If it is not possible you might use ucontext instead.
1080
1081 \subsection options_perf_guard_size Disabling stack guard pages
1082
1083 A stack guard page is usually used which prevents the stack from
1084 overflowing on other parts of the memory. However this might have a
1085 performance impact if a huge number of processes is created.  The
1086 option \b contexts:guard-size is the number of stack guard pages
1087 used. By setting it to 0, no guard pages will be used: in this case,
1088 you should avoid using small stacks (\b stack-size) as the stack will
1089 silently overflow on other parts of the memory.
1090
1091 \section options_index Index of all existing configuration options
1092
1093 \note
1094   Almost all options are defined in <i>src/simgrid/sg_config.c</i>. You may
1095   want to check this file, too, but this index should be somewhat complete
1096   for the moment (May 2015).
1097
1098 \note
1099   \b Please \b note: You can also pass the command-line option "--help" and
1100      "--help-cfg" to an executable that uses simgrid.
1101
1102 - \c clean-atexit: \ref options_generic_clean_atexit
1103
1104 - \c contexts/factory: \ref options_virt_factory
1105 - \c contexts/guard-size: \ref options_virt_parallel
1106 - \c contexts/nthreads: \ref options_virt_parallel
1107 - \c contexts/parallel_threshold: \ref options_virt_parallel
1108 - \c contexts/stack-size: \ref options_virt_stacksize
1109 - \c contexts/synchro: \ref options_virt_parallel
1110
1111 - \c cpu/maxmin-selective-update: \ref options_model_optim
1112 - \c cpu/model: \ref options_model_select
1113 - \c cpu/optim: \ref options_model_optim
1114
1115 - \c exception/cutpath: \ref options_exception_cutpath
1116
1117 - \c host/model: \ref options_model_select
1118
1119 - \c maxmin/precision: \ref options_model_precision
1120
1121 - \c msg/debug-multiple-use: \ref options_msg_debug_multiple_use
1122
1123 - \c model-check: \ref options_modelchecking
1124 - \c model-check/checkpoint: \ref options_modelchecking_steps
1125 - \c model-check/communications-determinism: \ref options_modelchecking_comm_determinism
1126 - \c model-check/dot-output: \ref options_modelchecking_dot_output
1127 - \c model-check/hash: \ref options_modelchecking_hash
1128 - \c model-check/property: \ref options_modelchecking_liveness
1129 - \c model-check/max-depth: \ref options_modelchecking_max_depth
1130 - \c model-check/record: \ref options_modelchecking_recordreplay
1131 - \c model-check/reduction: \ref options_modelchecking_reduction
1132 - \c model-check/replay: \ref options_modelchecking_recordreplay
1133 - \c model-check/send-determinism: \ref options_modelchecking_comm_determinism
1134 - \c model-check/sparse-checkpoint: \ref options_modelchecking_sparse_checkpoint
1135 - \c model-check/termination: \ref options_modelchecking_termination
1136 - \c model-check/timeout: \ref options_modelchecking_timeout
1137 - \c model-check/visited: \ref options_modelchecking_visited
1138
1139 - \c network/bandwidth-factor: \ref options_model_network_coefs
1140 - \c network/coordinates: \ref options_model_network_coord
1141 - \c network/crosstraffic: \ref options_model_network_crosstraffic
1142 - \c network/latency-factor: \ref options_model_network_coefs
1143 - \c network/maxmin-selective-update: \ref options_model_optim
1144 - \c network/model: \ref options_model_select
1145 - \c network/optim: \ref options_model_optim
1146 - \c network/sender_gap: \ref options_model_network_sendergap
1147 - \c network/TCP-gamma: \ref options_model_network_gamma
1148 - \c network/weight-S: \ref options_model_network_coefs
1149
1150 - \c ns3/TcpModel: \ref options_pls
1151 - \c path: \ref options_generic_path
1152 - \c plugin: \ref options_generic_plugin
1153
1154 - \c surf/nthreads: \ref options_model_nthreads
1155 - \c surf/precision: \ref options_model_precision
1156
1157 - \c <b>For collective operations of SMPI, please refer to Section \ref options_index_smpi_coll</b>
1158 - \c smpi/async-small-thresh: \ref options_model_network_asyncsend
1159 - \c smpi/bw-factor: \ref options_model_smpi_bw_factor
1160 - \c smpi/coll-selector: \ref options_model_smpi_collectives
1161 - \c smpi/comp-adjustment-file: \ref options_model_smpi_adj_file
1162 - \c smpi/cpu-threshold: \ref options_smpi_bench
1163 - \c smpi/display-timing: \ref options_smpi_timing
1164 - \c smpi/lat-factor: \ref options_model_smpi_lat_factor
1165 - \c smpi/IB-penalty-factors: \ref options_model_network_coefs
1166 - \c smpi/iprobe: \ref options_model_smpi_iprobe
1167 - \c smpi/init: \ref options_model_smpi_init
1168 - \c smpi/ois: \ref options_model_smpi_ois
1169 - \c smpi/or: \ref options_model_smpi_or
1170 - \c smpi/os: \ref options_model_smpi_os
1171 - \c smpi/privatize-global-variables: \ref options_smpi_global
1172 - \c smpi/running-power: \ref options_smpi_bench
1173 - \c smpi/send-is-detached-thresh: \ref options_model_smpi_detached
1174 - \c smpi/simulate-computation: \ref options_smpi_bench
1175 - \c smpi/test: \ref options_model_smpi_test
1176 - \c smpi/use-shared-malloc: \ref options_model_smpi_use_shared_malloc
1177 - \c smpi/wtime: \ref options_model_smpi_wtime
1178
1179 - \c <b>Tracing configuration options can be found in Section \ref tracing_tracing_options</b>.
1180
1181 - \c storage/model: \ref options_storage_model
1182 - \c verbose-exit: \ref options_generic_exit
1183
1184 - \c vm/model: \ref options_vm_model
1185
1186 \subsection options_index_smpi_coll Index of SMPI collective algorithms options
1187
1188 TODO: All available collective algorithms will be made available via the ``smpirun --help-coll`` command.
1189
1190 */